    Description

    Physical Specifications:
    Type Specification Comments: Weight 11.5 kg (26 lbs) Dimensions (width × depth × height) 345 × 435 × 140 mm (13.5 × 17 × 5.5 inches)
    Line voltage: 100 – 240 VAC, ± 10 % Wide-ranging capability Line frequency 50 or 60 Hz ± 5 %
    Power consumption (G1315B/65B): 300 VA / 125 W / 427 BTU
    Maximum Ambient operating temperature: 0 – 55 °C (32 – 131 °F) .
    Ambient non-operating temperature -40 – 70 °C (-4 – 158 °F)
    Humidity < 95%, at 25 – 40 °C (77 – 104 °F)
    Non-condensing Operating altitude Up to 2000 m (6500 ft)
    Non-operating altitude Up to 4600 m (14950 ft)
    For storing the detector Safety standards: IEC, CSA, UL, EN Installation category II, pollution degree 2. For indoor use only.
    Performance Specifications :
    Performance Specifications Agilent 1200 Series DAD
    Detection type 1024-element photodiode array
    Light source Deuterium and tungsten lamps
    Wavelength range 190 – 950 nm
    Short term noise (ASTM) Single and Multi-Wavelengt ± 1 × 10-5 AU at 254 and 750 nm
    Drift 2 × 10-3 AU/hr at 254 nm
    Linear absorbance range > 2 AU (upper limit)
    Wavelength accuracy ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter
    Wavelength bunching 1 – 400 nm Programmable in steps of 1 nm Slit width 1, 2, 4 , 8, 16 nm Programmable slit Diode width < 1 nm
    Flow cells Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum Micro: 2 µl volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum High pressure: 1.7 µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure maximum 80 nano: 0.08 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    Control and data evaluation Agilent ChemStation for LC
    Analog outputs Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    Safety and maintenance Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    GLP features Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.
    Housing All materials recyclable